ORBITON 45/80-80 HIMA

Reference standard PN-EN 14023:2011/Ap 1:2014

1. Description of the product

ORBITON 45/80-80 HiMA modified bitumen is used for pavement wearing courses subjected to very high loads and low temperature environments, as well as for other layers in specific locations, such as bridge structures.

 

2. Properties

Property Unit Method Requirement
Penetration at 25 oC 0,1 mm PN-EN 1426 45÷80
​Softening Point R&B oC PN-EN 1427​ ≥80
​Elastic recovery at 25 oC ​% ​PN-EN 13398 ≥80​
Elastic recovery at​ 10 oC ​% PN-EN 13398​ TBR​
​Fraass Breaking Point oC ​PN-EN 12593 ​≤-18
​Flash point, COC ​​​oC PN-EN ISO 2592​ ​≥235
​Force ductility ​J/cm2 ​PN-EN 13589
PN-EN 13703
≥2 w 10 oC​
​Mass change after RTFOT %​ PN-EN 12607-1​ ≤0,5​
​Increasing of Softening Point R&B oC PN-EN 1427​​ ≤8​
​Retained penetration ​% PN-EN 1426​ ≥60​
​Elastic recovery at  oC after RTFOT ​% ​PN-EN 12607-1,
PN-EN 13398
​≥60
​Elastic recovery at  10 oC after RTFOT ​%​  PN-EN 13398​ ​TBR
​Storage stability
Difference in Softening Point R&B
 oC ​PN-EN 13399,
PN-EN 1427
≤5​
Drop in softening point after RTFOT oC ​PN-EN 12607-1,
PN-EN 1427
TBR
 

Production plant: Płock

 
 